Product Introduction
The Lyser series analyzers can be applied to both automatic laboratory analysis and on-site online analysis of conventional water quality parameters in water samples, such as online measurement of heavy metal ions like copper, iron, nickel, chromium, cadmium, arsenic, mercury, and lead. Online analysis of Escherichia coli Online analysis of total organic carbon Online analysis of biological toxicity BOD online analysis Dozens of water quality indicators such as sulfide, fluoride, volatile phenol, phosphate, total phosphorus, total nitrogen, ammonia nitrogen and COD are particularly suitable for water quality monitoring and process detection of surface water, enterprise pollution sources, municipal sewage, etc.
Technical parameters of Lyser Series Online Total Manganese/Online manganese ion Analyzer
Measurement method: The actual situation shall prevail
Measurement range: Subject to actual conditions
Accuracy: ±10%
Repeatability: ±5%
Detection limit: Subject to actual conditions
Zero drift: ±5%
Range drift: ±5%
Measurement time: Approximately 40 minutes
Measurement mode: Interval measurement (arbitrary setting from 0 to 9999 minutes) and 24-hour whole-hour time measurement mode; Single measurement and reverse control measurement
Quality control: Regular automatic calibration and automatic verification of standard solutions can be set at any time point
Calibration mode: User manual calibration; Automatic calibration can be set at any time point on a regular basis
Communication port: RS-232 RS-485 RJ45
Measurement modes: Time interval, 24-hour whole-hour time measurement mode, single measurement mode, optional
Analog signal :4-20mA
Control signals :2 channels of digital output, 2 channels of digital input
Environmental requirements: Suggested temperature (5-33)℃; Humidity ≤85%(no condensation)
Power supply :(220±22)VAC,(50±0.5)Hz
Power efficiency :≤150W
Dimensions :Subject to actual conditions
Others:
It has the function of logging the operation process of the instrument. It can store the original data and operation logs for at least one year. Instrument abnormal alarm (including component failure alarm, over-range alarm, over-standard alarm, reagent shortage alarm and other information); Data is automatically saved in case of power failure. 10-inch TFT true-color LCD touch screen display and command input; In case of abnormal reset or power failure followed by power restoration, the working state will be automatically restored. Instrument status display function (such as measurement, idle, fault, maintenance, etc.); The instrument has three levels of management authority.