Online analyzers
Lyser-EC online Escherichia coli analyzer
product details

Product Features
The enzyme substrate fluorescence detection technology can be used for multiple purposes with one machine. The test indicators are “coliform bacteria” and “feces”
“Coliform bacteria” and “Escherichia coli” can be freely switched.
Detection time: 4 to 16 hours, which is 2 hours shorter than the national standard.
The test values are accurate, and the relative error of the concentration index is ≤10%.
According to the actual characteristics of water samples, quantitative quality control bacteria are regularly used (in accordance with national standard methods) for on-site quality control to ensure the reliability of the results.
The fluorescence method is adopted, and there are no special requirements for the turbidity of water samples.
It adopts non-disposable reagents, which are low-cost and support a 15-day maintenance-free cycle.
It has an automatic water sample replacement function, reducing the impact of the previous water sample concentration. The residual concentration of the previous concentration is less than 0.001%.
The liquid seals in the system pipelines before and after the detection, in combination with the sealed detection system, completely isolate the outside world and eliminate the influence of the environment on the detection results.
Dynamic simulation analysis flowchart, easy to maintain and understand;
High-performance integrated touch screen, visual operation interface, clearer display, smoother operation and more stable operation;

Technical parameters
Measurement principle: Enzyme substrate fluorescence method
Measurement range: 10^2 cfu/L to 10^12 cfu/L
Detection accuracy: EC50Zn2+≤2.0mg/L (ZnSO4 is the standard sample)
Detection limit: 1 per 10ml
Accuracy: ≤±10%(index)
Reaction time: 4 to 16 hours
Sampling volume: 10ml
Sampling frequency: ≥4 hours. It can be set according to the actual situation
Zero-point calibration: The instrument performs it automatically, once every maintenance cycle
Pipeline cleaning and disinfection: before and after each measurement
Communication port: RS-232 RS-485 RJ45
Measurement modes: Time interval, 24-hour whole-hour time measurement mode, single measurement mode, optional
Cultivation temperature and monitoring indicators:
44℃ monitoring refers to (heat-resistant (fecal) coliform bacteria)
37℃ monitoring refers to (coliform bacteria and Escherichia coli)
Negative quality control: ≥1 day, which can be set according to the actual situation
Alarm signals: temperature faults and instrument faults, etc
Minimum maintenance cycle: ≥168 hours
Analog signal :4-20mA
Control signals :2 channels of digital output, 2 channels of digital input
Environmental requirements: Suggested temperature (5-33)℃; Humidity ≤85%(no condensation)
Power supply :(220±22)VAC,(50±0.5)Hz
Power efficiency :≤200W
Dimensions :600*600*1600 mm