Product

Product
Online analyzers
UV Method COD analyzer UC1000/Lyter-COD
product details

Typical applications
Continuous monitoring of organic load during sewage treatment and online real-time monitoring of inlet and outlet water quality in sewage treatment plants;
Continuous online monitoring of surface water, industrial wastewater discharge, and fishery wastewater discharge
FEATURES
Probe direct immersion measurement without sampling and preprocessing;
No need for chemical reagents, secondary pollution;
Short response time, capable of continuous measurement;
The sensor has an automatic cleaning function, which can reduce maintenance.
Continuous monitoring of organic load during sewage treatment and online real-time monitoring of inlet and outlet water quality in sewage treatment plants;
Continuous online monitoring of surface water, industrial wastewater discharge, and fishery wastewater discharge
FEATURES
Probe direct immersion measurement without sampling and preprocessing;
No need for chemical reagents, secondary pollution;
Short response time, capable of continuous measurement;
The sensor has an automatic cleaning function, which can reduce maintenance.
UC1000-UV Controller Main Technical Parameter
Language selection: English, Simplified Chinese
output: 2-channel isolated 0/4~20mA, 500Ω Max
Calibration mode: Single-point or multi-point
communication: MODBUS RS485 protocol
Data recording: Built-in storage function
Relay control:250VAC 5A Max
Protection grade: IP66
Power supply: 100-240VAC, 50/60Hz, 24VDC, optional
Measurement range: 0-2000mg/L (2mm), 0-500/1000mg/L (5mm), 0-90mg/L (50mm)
Measurement accuracy: ± 5%
Resolution: 0.01 mg/L
Minimum detection limit: 0.1 mg/L
Measurement accuracy: ± 5%
Resolution: 0.01 mg/L
Minimum detection limit: 0.1 mg/L
Automatic turbidity compensation function (wavelength 550nm)
The cleaning function comes with a scraper cleaning function, and the interval can be adjusted
Communication output: RS485
Working temperature: 0-45 ℃
Storage temperature: -15~50 ℃
Pressure range: 0~0.4Mpa
Body material SUS316L (standard), titanium alloy (optional)
The standard cable length is 10m, and other options are available
Protection level: IP68/NEMA6P
The cleaning function comes with a scraper cleaning function, and the interval can be adjusted
Communication output: RS485
Working temperature: 0-45 ℃
Storage temperature: -15~50 ℃
Pressure range: 0~0.4Mpa
Body material SUS316L (standard), titanium alloy (optional)
The standard cable length is 10m, and other options are available
Protection level: IP68/NEMA6P
Product weight: Lyter II (approximately 3.2kg),
Lyter I (approximately 0.8kg)
Product dimensions: Lyter II 69mm * 365/368/413mm (D * L),
Product dimensions: Lyter II 69mm * 365/368/413mm (D * L),
Lyter I 34mm * 209mm (D * L)
- Previous: